Thread: Is approach release fail safe?
Post: RE: Is approach release fail safe?
Alasdair Wrote: (07-03-2010, 05:42 PM)
--
nagaraju_dw,
To the best of my knowledge for approach control, we use delta tracks (or position detectors or track circuits) to start a timing relay (JR) ... |
|
nagaraju_dvv |
Principles Queries etc
|
9 |
57,552 |
08-03-2010, 06:16 PM |
|
|
Thread: Is approach release fail safe?
Post: RE: Is approach release fail safe?
In London Underground, they use Delta Rail Circuit for approach control. Delta Rail Circuit is a 10kHz open circuit superimposed on existing AC track circuit,whose length is small. The Delta Circuit ... |
|
nagaraju_dvv |
Principles Queries etc
|
9 |
57,552 |
06-03-2010, 08:21 PM |
|
|
Thread: Is approach release fail safe?
Post: RE: Is approach release fail safe?
PJW Wrote: (12-01-2010, 08:42 PM)
--
Saraswathi Wrote: (12-01-2010, 07:57 PM)
--
Hi guys,
An interesting debate on "approach release"......
We approach release the signals to reduce the train ... |
|